SENSOMATIC-EMA

Measurement data acquisition and exact determination of overflow and flow rates in the application areas partial and full filling
SENSOMATIC-EMA 1

PRODUCT DESCRIPTION

The EMA (electronic volume evaluation) system offers an optimal solution for precise collection and evaluation of overflow quantities, which are relieved via weir thresholds. The EMA system consists of the following components:

EMA panel variable mechanical construction with E-scale optics for recording, protection and precise adjustment of the sensors

EMA sensors high-precision, continuous measurement recording and additional level set-points for calibrating

EMA controller high-resolution collection and archiving of measuring data per the Delta-Event process with verification and calibration functions

EMA evaluation operator-friendly data evaluation with graphic analysis tools and logging based on Microsoft Excel

EMA measuring profile structured measuring profile to equalise structural height differences and for precision improvement.

Your Advantages

  • Calibration and reference points via digital height benchmarks
  • Maintenance-friendly access and precise adjustment of the sensors.
  • Very precise measurement of the flood height
  • Long term archiving of raw and calculated values e.g. on a CF card.
  • High level of precision due to structured measuring profile.
  • Operator friendly evaluation.
  • Reporting system based on Excel in accordance with the official specifications.
  • Automatic sending of reports in PDF format
  • Alarm function

contact us

SENSOMATIC-EMA 2
Jörg Brandenburg

+49 (0) 291-9929-17
joerg.brandenburg@hst.de

EMA-Panel (Basic component)
Service-friendly access:
  • Possible to assemble the sensor from the top
  • Locks in after service (position and reference height
    the reference sensor remains unchanged)
Optical display and adjustment:
  • Optical display of relevant reference heights e.g. the upper edge of the weir threshold above an e-scaling with freely adjustable displays
  • Simple mechanical alignment and at the same time the exact adjustment of the height reference point for permanent calibration
Highly accurate sensors
  • High-resolution measurement of basic quantities, e.g. Level via hydrostatic probe / or radar measurement error: max. 1 mm / 2 mm
  • An exact reference value for calibration, e.g. Level limit value via capacitive measuring probe
    assured switching distance: < 1 mm
  • Approval for use in EX-protection zones
EMA-Measuring profile
  • To improve accuracy
  • To compensate for structural height differences at the overflow edge
  • For the structure of the cross-sectional or flow-through profile
EMA-Measuring profile
  • High-resolution data acquisition
  • Capture reference signal
  • Review readings
  • Preparation of measured values
  • Archiving according to delta event procedure
  • Direct data transmission (e.g. GPRS)
SENSOMATIC-EMA 3
EMA-System Module

The HST EMA system is the optimal solution for high-precision determination and evaluation of overflow or discharge rates at fixed weir thresholds, movable valves / weirs and in relief lines, as well as for flow or discharge rate measurement in channels and piping in the application areas partial and full filling. The HST EMA modular system offers the right system components for every task.

SENSOMATIC-EMA 4

你身边的HST

Deutschland HST 中国

HST Systemtechnik

上海市静安区
天目西路218号
第一座2010室

021-62522886
info@hst-water.cn

你身边的HST

Deutschland HST 中国

HST Systemtechnik

上海市静安区
天目西路218号
第一座2010室

021-62522886
info@hst-water.cn

SENSOMATIC-EMA 5

references

  • Hamburg Airport GmbH
    Flow measurement surface and rainwater, here combination flow measurement in open channels and overflow measurement at fixed weir threshold
  • Municipal utilities Bochum discharge quantity measurement in special structures in the sewage network on fixed weirs, flaps and in discharge channels
  • Economics Business Hagen discharge quantity measurement in special structures in the sewage network at fixed weir barriers, too, part under difficult hydraulic conditions (long threshold with non-linear flow behavior)
  • Municipality of Neuhausen ob Eck
    Drain and relief flow measurement Wastewater treatment plant and drainage measurement Retention soil filter system
  • City council Metzingen / Disposal business Remscheider / Lengerich city / Local community Ebhausen / Geseke city / Babenhausen market / Unna public utilities
    Relief volume measurements in special structures in the sewer system on fixed weir sleepers with high accuracy through the additional use of articulated measuring profiles

downloads

Watervision - Know-how...

Measurement and logging of accumulation and discharge events with SensoMatic-EMA

SENSOMATIC-EMA 6

We have summarized important information on the topic of measuring and logging congestion and relief events as a guide for you.

We would be pleased to inform you about the various applications, measuring principles and expansion options, also for increasing the accuracy as well as the automatic calibration of the EMA system.

On request, you will receive the printed copy by mail or via e-mail as an e-paper.